Special Chillers

This guide examines industries and career paths for architecturegraduates, as well as resources that can help professionals.

CHILLERS WITH OIL-FREE CENTRIFUGAL COMPRESSORS WITH MAGNETIC LEVITATION

Magnetic Levitation
oil-free-compressor
Intermediate Chillers

AIR-COOLED UNITS (60 to 400 tons)

Outdoor unit for the production of chilled water featuring oil-free centrifugal compressor, axial-flow fans, condensing coil with copper tubes and aluminium fins, shell & tube flooded evaporator and electronic regulation valve. Base and supporting structure and panels are made of galvanized epoxy powder-coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation, coupled with the use of inverter technology. The compressor is radically innovative: magnetic bearings and digital rotor speed control allow partial load efficiency levels never reached before.

Large Chillers - Advantages

FEATURES

VERY HIGH EFFICIENCY
 
Very high efficiency at full and partial load, to top market levels, thanks to adopted technological solutions: large capacity modulation and expanded exchanger, offering minimum running costs of the unit in real working conditions.
EXTREMELY SILENT OPERATION
As result of a systematic design oriented to minimize the noise level, XL versionu00b4s units give the best compromise between silence and efficiency on the market.
VERSION CA-E AVAILABLE
Version CA-E is characterized by efficiency beyond the Class A for Eurovent. The technological choices adopted assure minimal operating costs and therefore quick payback time.
LOW INRUSH CURRENTS
Reduced breakaway starting currents thanks to the revolutionary centrifugal compressor.

WATER-COOLED UNITS (60 to 550 tons)

Indoor unit for the production of chilled water featuring centrifugal compressors oil-free, electronic regulation valve, shell and tube condenser and shell and tube flooded evaporator. Base and supporting structure and panels are made of galvanized epoxy powder-coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation, coupled with the use of inverter technology. The compressor is radically innovative: magnetic bearings and digital rotor speed control allow partial load efficiency levels to be reached that were hitherto impossible.

Water Cooled Units
Large Chillers - Advantages

FEATURES

DEDICATED VERSIONS
 
Dedicated versions for different applications: version HC, High Condensing, for dry-cooler or heat pump systems and version LC, Low Condensing, for cooling tower or ground source applications.
HEAT PUMP FUNCTION
Heat pump function water circuit side reversal.
EXTREMELY SILENT OPERATION
Extremely silent operation in line with the best in the market, and highly reduced vibrations.